Module No.
HS-MA-900-3×3P-100-QCW

Model No. | HS-MA-3-40-SW808 | HS-MA-3-20-SW808 | HS-MA-4-40-SW808 | HS-MA-4-20-SW808 | HS-MA-900-3×3P-100-QCW |
---|---|---|---|---|---|
Optical parameters | |||||
Output power(W) | 60 | 60 | 80 | 80 | 900 |
Center Wavelength at 25 °C(nm)² | 808 or upon request | ||||
Number of sub-mounts in one heat sink | 3 | 4 | 9 | ||
Each Bar power(W) | 40 | 20 | 40 | 20 | 100 |
Center Wavelength Variation at 25 °C(nm)² | ±2 | ||||
Typical Spectral Bandwidth (FWHM) | <3 | ||||
Divergence(degree)(FWHM) | <39⊥<10‖ | ||||
Polarization | TE | ||||
Wavelength shift(nm/℃) | ~0.28 | ||||
Electrical Parameters | |||||
Working mode | CW | QCW | |||
Operation Current(A) | 25 | 20 | 25 | 20 | 100 |
Operating Voltage(V) | ≦6 | ≦8 | ≦18 | ||
Max duty circle(%) | / | 10 | |||
Typical Slope per bar(W/A) | >1.1 | ||||
Electro-optic Conversion Efficiency(%) | >50 | ||||
Thermal parameters | |||||
Operation Temperature(℃) | -40~60 | ||||
Storage Temperature(℃) | -50~85 | ||||
Storage humidity(%) | <70 | ||||
Cooling | Water cooled |
1. The wavelengths of each bar in a single device can be arranged and combined according to the heat dissipation conditions.
2. The above parameters are measured at the heat sink temperature of 25°C.
3. Heat sink structure can be customized according to customer’s special requirements.
Drawing